Skip to content

Spend your time on design, not on admin.

Archie reads every drawing, email and regulation that comes in, checks it against what was decided, and tells you everything it affects.

Works with Revit Autodesk Docs SharePoint Email PDF Excel Word

ARCHITECTS AND CONSULTANTS

54%

of the week wasted on managing information, not design

Stanford CIFE, 2007 ↗

2 of 3

architects work unpaid overtime

RIBA, 2025 ↗

PROPERTY DEVELOPERS

169 000 kr

lost per home, per year of delay

Samfunnsøkonomisk analyse, 2024 ↗

3 of 4

new homes have a building error

Menon for DiBK, 2022 ↗

3 of 4

building errors start in design

Menon for DiBK, 2022 ↗

HOW IT WORKS · ONE CHANGE, START TO FINISH

01Information comes in
02Archie checks it
03You decide
04Archie records it
05Archie tracks what it affects
archieHarbor HouseKari Sanders
MONDAY 9 NOVEMBER
PDF

Room programme v4.pdf

Ole Hansen, developer · uploaded to SharePoint

09:10
Archie
Conflict found09:12

Ole Hansen uploaded a new room programme. I checked it against the project: the ground-floor shops now need 3.0 m ceiling height, but the drawings still show 2.8 m.

PDFRoom programme v4.pdf · p. 12↗DWGSection A-301↗

DIRECTLY AFFECTED

Section A-301Still drawn at 2.8 mDWGA-301↗
Structural gridFloor height set for 2.8 mRVTRIB model rev. 3↗
Facade, level 1Windows sized for 2.8 mDWGF-201↗

INDIRECTLY AFFECTED

↳
Structural grid → building heightLevel 1 rises 0.2 m. The building reaches 23.8 m of the 24.0 m allowed.PDFZoning plan §4↗
↳
Facade, level 1 → window headsAll 6 shop windows need new window heads.DWGF-201↗
Archie

Suggestion: keep 3.0 m and update A-301, the grid and the facade on level 1. The building stays under the height limit. Record 3.0 m as the decision?

✓ ApprovedDeny
Kari Sanders approved · recorded as decision 52 · Mon 9 Nov 2026, 11:30

Show me what depends on it.

KS
Archie

4 things depend on decision 52. If one changes, I check again.

11:34
Section A-301needs update›
Facade, level 1needs update›
F-201 - ELEVATIONS ×1 : 100
ABCDEFGHJKLMNROOF+13.800LEVEL 4+10.350LEVEL 3+6.900LEVEL 2+3.450LEVEL 1±0.000HEAD +3.000 · DECISION 525230001F-201SOUTH ELEVATION1 : 100
6 window heads drawn at +2.800. Decision 52 says +3.000. RVTShow in Revit
Structural gridto check›
Building heightto check›
Ask Archie about Harbor House…
Illustrative project data

Connect once.

Archie reads, checks, tracks and notifies you. Continuously.

WHAT COMES IN

WHAT ARCHIE DOES

Revit
Autodesk Docs
SharePoint
Email
Meeting notes
PDF, Excel, Word
Dalux, on invite
Teams, soon
Archie
Readsevery file, model and email
Checksagainst what was decided
Trackswhat each decision affects
Notifies youwhen something needs you

Why use Archie?

ARCHITECTS AND CONSULTANTS

use it every day

1 day/week back.

Archie does the checking for you.

No digging for why.

Every decision, with its source, one question away.

Full control of the project.

Every decision, requirement and change, tracked for you.

PROPERTY DEVELOPERS

own the record

Less risk on every big decision.

Every dependency on the table before you sign.

No redesign chain.

The ripple shows on day one, not two years later.

The record is yours.

For this project, and the next one.

Everything about the project, at your fingertips.

Every requirement and decision, with its full history and the page it came from.

HHHarbor House
Ask Archie
Project details
Requirements
Decisions3
Sources
Recent
Parking stall widthShop ceiling heightAll conversations
Settings
KSKari Sanders
RequirementsAsk
Search requirements, sources, decisions…FilterView
Harbor House › Underground › Parking › Dimensions · 4 requirements
RequirementSourceDecision
Dimensions 4
Parking stall widthParkeringsnorm 2026p. 64 decisions
Driving aisle widthParkeringsnorm 2026p. 7No open decision
Clear heightTEK17p. 12No open decision
Accessible stallsAccessibility reportp. 112 decisions
Parking stall width
RequirementHistory
Underground / Parking / Dimensions Minimum 2.5 m. Compact stalls 2.3 m, at most 20 % of stalls.
Source evidenceParkeringsnorm 2026 · p. 6 · Open sourceOriginal: “Parkeringsplasser skal ha en minste bredde på 2,5 m…”
Decided → Decision 61Cut compact stalls from 30 % to 20 %
TypeRegulation
ModalityMust
CheckabilityAutomatic, in Revit
Parkeringsnorm 2026Version 2
minste bredde1 of 1
Fjordby kommuneParkeringsnorm 2026 · Vedtatt 14.05.2026

§ 4 Utforming av parkeringsplasser

4.1 Parkeringsanlegg skal utformes slik at plassene er enkle å bruke, og slik at kjøreareal og gangareal er tydelig adskilt. Bestemmelsene gjelder for nye anlegg og for vesentlige endringer i eksisterende anlegg.

4.2 Parkeringsplasser skal ha en minste bredde på 2,5 m. Inntil 20 % av plassene kan utformes som kompaktplasser med bredde 2,3 m. Plasser langs vegg eller søyle skal ha 0,3 m tillegg i bredde.

4.3 Kjørebane mellom plasser skal være minst 6,0 m ved vinkelrett oppstilling. Minste fri høyde i anlegget er 2,2 m, og 2,5 m ved plasser for bevegelseshemmede.

Tabell 2 – Minstemål for parkeringsplasser
Type plassBreddeLengdeAndel
Standard2,5 m5,0 m–
Kompakt2,3 m4,5 mmaks. 20 %
Bevegelseshemmede (HC)4,5 m6,0 mmin. 5 %

4.4 Minst 5 % av plassene, og minimum én plass, skal være tilrettelagt for bevegelseshemmede og ligge nær inngang. Avvik fra tabell 2 krever dispensasjon etter plan- og bygningsloven § 19-2.

6
Page 6 of 18−100%+
Illustrative project data

Make your model
work for you.

Archie inside Autodesk Revit, checking doors on level L3
Autodesk Revit 2027.1 - Snowdon Towers Sample Architectural.rvt - Floor Plan: L3
kari.sanders
!
!
2' 9 1/2"
304A
55
57
59
Single-Flush33 1/2" x 84"
Doors (1)⊞ Edit Type
Constraints⌃
LevelL3
Sill Height0' 0"
Dimensions⌃
Width2' 9 1/2"
Height7' 0"
Identity Data⌃
Mark304A
From RoomCorridor 302
To RoomStudio Unit 304
CommentsArchie: below brief
Phasing⌃
Phase CreatedNew Construction
Doors : Single-Flush : 33 1/2" x 84" : Mark 304A
Snowdon Towers · L3▾
ChecksAsk
Door clear width
Min. 900 mm clear in homes · 64 doors on L3 Client brief rev 4 · §3.2, p. 14 Run check
Checked 64 doors · 14 requirements
62 pass
2 to look at
304A850 mm · Studio 304›
306A870 mm · Unit 306›
Door 304A is 850 mm clear. The brief asks for 900 mm. Client brief rev 4 · p. 14
Selected in viewNext
Ask Archie about this project…

Not in Revit? Open the model in Archie, on any device.

Illustrative project data

Your project data stays yours.

Hosted in the EU

Files and models stay on EU servers.

Never used for training

Your files never train models.

You confirm what happens

Nothing changes without a person deciding.

GDPR compliant

Personal data handled under EU rules.

Why we built Archie

Orsi spent over ten years as an architect on large, complex projects. Archie is what she wished those projects had. Stefan, a three-time software founder, joined to build it.

Orsolya Gunthner, CEO · Stefan Gasser, CTO

Innovation NorwayGoogle for StartupsNVIDIA Inception
Orsolya Gunthner and Stefan Gasser, founders of Archie

Projects became information systems.

Now they run like one.

Book a call Bring one project. We look at it with you.

Book a demo

Tell us about your practice and one live project. We’ll reply by email to find a time.

We only use your details to reply to your request. Privacy policy